Search Results (795 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-11739 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reporting And Dashboards 2026-03-11 N/A
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2025-13957 1 Schneider-electric 1 Struxureware Data Center Expert 2026-03-11 N/A
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13901 1 Schneider-electric 2 Modicon M241/m251, Modicon M262 2026-03-11 N/A
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-13902 1 Schneider-electric 2 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058 2026-03-11 N/A
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2026-1286 1 Schneider-electric 1 Foxboro Dcs 2026-03-11 N/A
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.
CVE-2026-2273 1 Schneider-electric 1 Ecostruxure Automation Expert 2026-03-11 N/A
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.
CVE-2025-13844 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-03-03 5.3 Medium
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2026-02-25 5.3 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2026-1227 1 Schneider-electric 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation 2026-02-11 N/A
CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized disclosure of local files, interaction within the EBO system, or denial of service conditions when a local user uploads a specially crafted TGML graphics file to the EBO server from Workstation.
CVE-2026-1226 1 Schneider-electric 2 Ecostruxure Building Operation Webstation, Ecostruxure Building Operation Workstation 2026-02-11 N/A
CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-01-30 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-13845 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-01-16 N/A
CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2025-11567 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-14 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.
CVE-2025-11566 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-12 N/A
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint.
CVE-2025-11565 1 Schneider-electric 1 Powerchute Serial Shutdown 2025-11-12 N/A
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload.
CVE-2018-7841 1 Schneider-electric 1 U.motion Builder 2025-11-03 9.8 Critical
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2019-6833 1 Schneider-electric 49 Hmig2u, Hmig3u, Hmig3ufc and 46 more 2025-09-30 6.5 Medium
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high rate of frames is received. When the attack stops, the buffered commands are processed by the HMI panel.
CVE-2023-5984 1 Schneider-electric 4 Ion8650, Ion8650 Firmware, Ion8800 and 1 more 2025-09-30 7.2 High
A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device.
CVE-2014-0789 1 Schneider-electric 5 Opc Factory Server Tlxcdlfofs, Opc Factory Server Tlxcdltofs, Opc Factory Server Tlxcdluofs and 2 more 2025-09-25 N/A
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.