Search Results (1953 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-24329 2 Jetbrains, Oracle 3 Kotlin, Communications Cloud Native Core Binding Support Function, Communications Pricing Design Center 2024-11-21 5.3 Medium
In JetBrains Kotlin before 1.6.0, it was not possible to lock dependencies for Multiplatform Gradle Projects.
CVE-2022-24316 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 High
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24139 1 Iobit 1 Advanced System Care 2024-11-21 7.8 High
In IOBit Advanced System Care (AscService.exe) 15, an attacker with SEImpersonatePrivilege can create a named pipe with the same name as one of ASCService's named pipes. ASCService first tries to connect before trying to create the named pipes, because of that during login the service will try to connect to the attacker which will lead to either escalation of privileges (through token manipulation and ImpersonateNamedPipeClient() ) from ADMIN -> SYSTEM or from Local ADMIN-> Domain ADMIN depending on the user and named pipe that is used.
CVE-2022-24074 1 Navercorp 1 Whale 2024-11-21 9.8 Critical
Whale Bridge, a default extension in Whale browser before 3.12.129.18, allowed to receive any SendMessage request from the content script itself that could lead to controlling Whale Bridge if the rendering process compromises.
CVE-2022-23835 1 Visual Voice Mail Project 1 Visual Voice Mail 2024-11-21 8.1 High
The Visual Voice Mail (VVM) application through 2022-02-24 for Android allows persistent access if an attacker temporarily controls an application that has the READ_SMS permission, and reads an IMAP credentialing message that is (by design) not displayed to the victim within the AOSP SMS/MMS messaging application. (Often, the IMAP credentials are usable to listen to voice mail messages sent before the vulnerability was exploited, in addition to new ones.) NOTE: some vendors characterize this as not a "concrete and exploitable risk.
CVE-2022-23825 5 Amd, Debian, Fedoraproject and 2 more 253 A10-9600p, A10-9600p Firmware, A10-9630p and 250 more 2024-11-21 6.5 Medium
Aliases in the branch predictor may cause some AMD processors to predict the wrong branch type potentially leading to information disclosure.
CVE-2022-23163 1 Dell 1 Emc Powerscale Onefs 2024-11-21 4.7 Medium
Dell PowerScale OneFS, 8.2,x, 9.1.0.x, 9.2.1.x, and 9.3.0.x contain a denial of service vulnerability. A local malicious user could potentially exploit this vulnerability, leading to denial of service/data unavailability.
CVE-2022-23118 1 Jenkins 1 Debian Package Builder 2024-11-21 8.8 High
Jenkins Debian Package Builder Plugin 1.6.11 and earlier implements functionality that allows agents to invoke command-line `git` at an attacker-specified path on the controller, allowing attackers able to control agent processes to invoke arbitrary OS commands on the controller.
CVE-2022-22815 3 Debian, Python, Redhat 3 Debian Linux, Pillow, Enterprise Linux 2024-11-21 6.5 Medium
path_getbbox in path.c in Pillow before 9.0.0 improperly initializes ImagePath.Path.
CVE-2022-22719 6 Apache, Apple, Debian and 3 more 9 Http Server, Mac Os X, Macos and 6 more 2024-11-21 7.5 High
A carefully crafted request body can cause a read to a random memory area which could cause the process to crash. This issue affects Apache HTTP Server 2.4.52 and earlier.
CVE-2022-22657 1 Apple 3 Garageband, Logic Pro X, Macos 2024-11-21 7.8 High
A memory initialization issue was addressed with improved memory handling. This issue is fixed in Logic Pro 10.7.3, GarageBand 10.4.6, macOS Monterey 12.3. Opening a maliciously crafted file may lead to unexpected application termination or arbitrary code execution.
CVE-2022-22515 1 Codesys 18 Control For Beaglebone Sl, Control For Beckhoff Cx9020, Control For Empc-a\/imx6 Sl and 15 more 2024-11-21 8.1 High
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
CVE-2022-22186 1 Juniper 2 Ex4650, Junos 2024-11-21 7.2 High
Due to an Improper Initialization vulnerability in Juniper Networks Junos OS on EX4650 devices, packets received on the management interface (em0) but not destined to the device, may be improperly forwarded to an egress interface, instead of being discarded. Such traffic being sent by a client may appear genuine, but is non-standard in nature and should be considered as potentially malicious. This issue affects: Juniper Networks Junos OS on EX4650 Series: All versions prior to 19.1R3-S8; 19.2 versions prior to 19.2R3-S5; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2; 22.1 versions prior to 22.1R1.
CVE-2022-22175 1 Juniper 45 Junos, Mx10, Mx10000 and 42 more 2024-11-21 7.5 High
An Improper Locking vulnerability in the SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated networked attacker to cause a flowprocessing daemon (flowd) crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can occur in a scenario where the SIP ALG is enabled and specific SIP messages are being processed simultaneously. This issue affects: Juniper Networks Junos OS on MX Series and SRX Series 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R2; 21.3 versions prior to 21.3R1-S1, 21.3R2. This issue does not affect Juniper Networks Junos OS versions prior to 20.4R1.
CVE-2022-22169 1 Juniper 2 Junos, Junos Os Evolved 2024-11-21 5.9 Medium
An Improper Initialization vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an attacker who sends specific packets in certain orders and at specific timings to force OSPFv3 to unexpectedly enter graceful-restart (GR helper mode) even though there is not any Grace-LSA received in OSPFv3 causing a Denial of Service (DoS). Unexpectedly entering GR helper mode might cause the OSPFv3 neighbor adjacency formed on this interface to be stuck in the "INIT" state which can be observed by issuing the following command: user@device> show ospf3 neighbor ID Interface State xx.xx.xx.xx ae100.0 Init <<<<<<<<<< An indicator of compromise can be seen in log files when traceoptions for OSPFv3 are enabled before the issue occurs. These logfile messages are as follows: OSPF restart signaling: Received hello with LR bit set from nbr ip=xx::xx id=xx.xx.xx.xx. Set oob-resync capabilty 1. OSPF Restart Signaling: Start helper mode for nbr ip xx::xx id xx.xx.xx.xx OSPF restart signaling: abort helper mode for nbr ip=xx::xx id=xx.xx.xx.xx OSPF neighbor xx::xx (realm ipv6-unicast <interface.unit> area xx.xx.xx.xx) state changed from Full to Init due to 1WayRcvd (event reason: neighbor is in one-way mode) (nbr helped: 0) This issue affects: Juniper Networks Junos OS. 15.1 versions prior to 15.1R7-S11; 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S7, 19.2R3-S4; 19.3 versions prior to 19.3R2-S7, 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. This issue does not affect any version of Juniper Networks Junos OS 12.3. This issue affects Juniper Networks Junos OS Evolved all versions prior to 21.2R2-EVO.
CVE-2022-22164 1 Juniper 1 Junos Os Evolved 2024-11-21 6.5 Medium
An Improper Initialization vulnerability in Juniper Networks Junos OS Evolved may cause a commit operation for disabling the telnet service to not take effect as expected, resulting in the telnet service staying enabled. When it is not intended to be operating on the device, an administrator can issue the following command to verify whether telnet is operating in the background: user@device > show system connections | grep :23 tcp 0 0 0.0.0.0:23 0.0.0.0:* LISTEN 20879/xinetd This issue affects: Juniper Networks Junos OS Evolved All versions prior to 20.4R2-S2-EVO; 21.1 version 21.1R1-EVO and later versions; 21.2 versions prior to 21.2R2-EVO.
CVE-2022-22154 1 Juniper 1 Junos 2024-11-21 6.8 Medium
In a Junos Fusion scenario an External Control of Critical State Data vulnerability in the Satellite Device (SD) control state machine of Juniper Networks Junos OS allows an attacker who is able to make physical changes to the cabling of the device to cause a denial of service (DoS). An SD can get rebooted and subsequently controlled by an Aggregation Device (AD) which does not belong to the original Fusion setup and is just connected to an extended port of the SD. To carry out this attack the attacker needs to have physical access to the cabling between the SD and the original AD. This issue affects: Juniper Networks Junos OS 16.1R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R3-S4. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.
CVE-2022-21947 1 Suse 1 Rancher Desktop 2024-11-21 8.3 High
A Exposure of Resource to Wrong Sphere vulnerability in Rancher Desktop of SUSE allows attackers in the local network to connect to the Dashboard API (steve) to carry out arbitrary actions. This issue affects: SUSE Rancher Desktop versions prior to V.
CVE-2022-21775 2 Google, Mediatek 46 Android, Mt2601, Mt6761 and 43 more 2024-11-21 6.7 Medium
In sched driver, there is a possible use after free due to improper locking. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06479032; Issue ID: ALPS06479032.
CVE-2022-20917 1 Cisco 1 Jabber 2024-11-21 4.3 Medium
A vulnerability in the Extensible Messaging and Presence Protocol (XMPP) message processing feature of Cisco Jabber could allow an authenticated, remote attacker to manipulate the content of XMPP messages that are used by the affected application. This vulnerability is due to the improper handling of nested XMPP messages within requests that are sent to the Cisco Jabber client software. An attacker could exploit this vulnerability by connecting to an XMPP messaging server and sending crafted XMPP messages to an affected Jabber client. A successful exploit could allow the attacker to manipulate the content of XMPP messages, possibly allowing the attacker to cause the Jabber client application to perform unsafe actions.