Search Results (2 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-21902 2 Juniper, Juniper Networks 8 Junos Os Evolved, Ptx10001-36mr, Ptx10002-36qdd and 5 more 2026-03-30 9.8 Critical
An Incorrect Permission Assignment for Critical Resource vulnerability in the On-Box Anomaly detection framework of Juniper Networks Junos OS Evolved on PTX Series allows an unauthenticated, network-based attacker to execute code as root. The On-Box Anomaly detection framework should only be reachable by other internal processes over the internal routing instance, but not over an externally exposed port. With the ability to access and manipulate the service to execute code as root a remote attacker can take complete control of the device. Please note that this service is enabled by default as no specific configuration is required. This issue affects Junos OS Evolved on PTX Series: * 25.4 versions before 25.4R1-S1-EVO, 25.4R2-EVO. This issue does not affect Junos OS Evolved versions before 25.4R1-EVO. This issue does not affect Junos OS.
CVE-2025-52961 1 Juniper 6 Junos Os Evolved, Ptx10001-36mr, Ptx10002-36qdd and 3 more 2026-01-23 6.5 Medium
An Uncontrolled Resource Consumption vulnerability in the Connectivity Fault Management (CFM) daemon and the Connectivity Fault Management Manager (cfmman) of Juniper Networks Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016 allows an unauthenticated, adjacent attacker to cause a Denial-of-Service (DoS). An attacker on an adjacent device sending specific valid traffic can cause cfmd to spike the CPU to 100% and cfmman's memory to leak, eventually to cause the FPC crash and restart. Continued receipt and processes of these specific valid packets will sustain the Denial of Service (DoS) condition. An indicator of compromise is to watch for an increase in cfmman memory rising over time by issuing the following command and evaluating the RSS number. If the RSS is growing into GBs then consider restarting the device to temporarily clear memory.   user@device> show system processes node fpc<num> detail | match cfmman Example:    show system processes node fpc0 detail | match cfmman    F S UID       PID       PPID PGID   SID   C PRI NI  ADDR SZ    WCHAN   RSS     PSR STIME TTY         TIME     CMD   4 S root      15204     1    15204  15204 0 80  0   - 90802     -      113652   4  Sep25 ?           00:15:28 /usr/bin/cfmman -p /var/pfe -o -c /usr/conf/cfmman-cfg-active.xml This issue affects Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016: * from 23.2R1-EVO before 23.2R2-S4-EVO, * from 23.4 before 23.4R2-S4-EVO, * from 24.2 before 24.2R2-EVO, * from 24.4 before 24.4R1-S2-EVO, 24.4R2-EVO. This issue does not affect Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016 before 23.2R1-EVO.