| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| A security flaw involving hard-coded credentials in LevelOne WBR-6012's web services allows attackers to gain unauthorized access during the first 30 seconds post-boot. Other vulnerabilities can force a reboot, circumventing the initial time restriction for exploitation.The password string can be found at addresses 0x 803cdd0f and 0x803da3e6:
803cdd0f 41 72 69 65 ds "AriesSerenaCairryNativitaMegan"
73 53 65 72
65 6e 61 43
...
It is referenced by the function at 0x800b78b0 and simplified in the pseudocode below:
if (is_equal = strcmp(password,"AriesSerenaCairryNativitaMegan"){
ret = 3;}
Where 3 is the return value to user-level access (0 being fail and 1 being admin/backdoor).
While there's no legitimate functionality to change this password, once authenticated it is possible manually make a change by taking advantage of TALOS-2024-XXXXX using HTTP POST paramater "Pu" (new user password) in place of "Pa" (new admin password). |
| A security flaw involving hard-coded credentials in LevelOne WBR-6012's web services allows attackers to gain unauthorized access during the first 30 seconds post-boot. Other vulnerabilities can force a reboot, circumventing the initial time restriction for exploitation.The backdoor string can be found at address 0x80100910
80100910 40 6d 21 74 ds "@m!t2K1"
32 4b 31 00
It is referenced by the function located at 0x800b78b0 and is used as shown in the pseudocode below:
if ((SECOND_FROM_BOOT_TIME < 300) &&
(is_equal = strcmp(password,"@m!t2K1")) {
return 1;}
Where 1 is the return value to admin-level access (0 being fail and 3 being user). |
| An attacker with local access to the medical office computer can
access restricted functions of the Elefant Service tool by using a
hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software. |
| A vulnerability, which was classified as problematic, has been found in Cosmote Greece What's Up App 4.47.3 on Android. This issue affects some unknown processing of the file gr/desquared/kmmsharedmodule/db/RealmDB.java of the component Realm Database Handler. The manipulation of the argument defaultRealmKey leads to use of default cryptographic key. Local access is required to approach this attack. The complexity of an attack is rather high. The exploitation is known to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| LB-LINK BL-WR 1300H v.1.0.4 contains hardcoded credentials stored in /etc/shadow which are easily guessable. |
| A vulnerability in Cisco Firepower Threat Defense (FTD) Software for Cisco Firepower 1000, 2100, 3100, and 4200 Series could allow an unauthenticated, local attacker to access an affected system using static credentials.
This vulnerability is due to the presence of static accounts with hard-coded passwords on an affected system. An attacker could exploit this vulnerability by logging in to the CLI of an affected device with these credentials. A successful exploit could allow the attacker to access the affected system and retrieve sensitive information, perform limited troubleshooting actions, modify some configuration options, or render the device unable to boot to the operating system, requiring a reimage of the device. |
| IBM Flexible Service Processor (FSP) FW860.00 through FW860.B3, FW950.00 through FW950.C0, FW1030.00 through FW1030.61, FW1050.00 through FW1050.21, and FW1060.00 through FW1060.10 has static credentials which may allow network users to gain service privileges to the FSP. |
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| MXsecurity software versions v1.1.0 and prior are vulnerable because of the use of hard-coded credentials. This vulnerability could allow an attacker to tamper with sensitive data. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| SSL Pinning Bypass in eWeLink Some hardware products allows local ATTACKER to Decrypt TLS communication and Extract secrets to clone the device via Flash the modified firmware |
| Certain switch models from PLANET Technology have a Hard-coded community string in the SNMPv1 service, allowing unauthorized remote attackers to use this community string to access the SNMPv1 service with read-write privileges. |
| Certain switch models from PLANET Technology have a Hard-coded Credential in the password recovering functionality, allowing an unauthenticated attacker to connect to the device via the serial console and use this credential to reset any user's password. |
| Certain switch models from PLANET Technology have a hard-coded credential in the specific command-line interface, allowing remote attackers with regular privilege to log in with this credential and obtain a Linux root shell. |
| Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the BLE AppAuthenRequest command handler. The handler uses hardcoded credentials as a fallback in case of an authentication request failure. An attacker can leverage this vulnerability to bypass authentication on the system.
Was ZDI-CAN-23196 |
| The web application for ProGauge MAGLINK LX4 CONSOLE contains an
administrative-level user account with a password that cannot be
changed. |
| Kastle Systems firmware prior to May 1, 2024, contained a hard-coded credential, which if accessed may allow an attacker to access sensitive information. |
| IBM MaaS360 for Android 6.31 through 8.60 is using hard coded credentials that can be obtained by a user with physical access to the device. |