| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created
over the web interface HTTP when enabled. HTTP is disabled by default. |
| A remote code execution vulnerability exists in CryptoLog (PHP version, discontinued since 2009) due to a chained exploitation of SQL injection and command injection vulnerabilities. An unauthenticated attacker can gain shell access as the web server user by first exploiting a SQL injection flaw in login.php to bypass authentication, followed by command injection in logshares_ajax.php to execute arbitrary operating system commands.
The login bypass is achieved by submitting crafted SQL via the user POST parameter. Once authenticated, the attacker can abuse the lsid POST parameter in the logshares_ajax.php endpoint to inject and execute a command using $(...) syntax, resulting in code execution under the web context.
This exploitation path does not exist in the ASP.NET version of CryptoLog released since 2009. |
| An unauthenticated command injection vulnerability exists in Serviio Media Server versions 1.4 through 1.8 on Windows, in the /rest/action API endpoint exposed by the console component (default port 23423). The checkStreamUrl method accepts a VIDEO parameter that is passed unsanitized to a call to cmd.exe, enabling arbitrary command execution under the privileges of the web server. No authentication is required to exploit this issue, as the REST API is exposed by default and lacks access controls. |
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. |
| The iSherlock developed by Hgiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. This vulnerability has already been exploited. Please update immediately. |
| A vulnerability, which was classified as critical, was found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. Affected is the function reboot/restore of the file /cgi-bin/lighttpd.cgi of the component Web Interface. The manipulation leads to improper authentication. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability, which was classified as critical, has been found in D-Link DIR-825 2.10. This issue affects the function sub_410DDC of the file switch_language.cgi of the component httpd. The manipulation of the argument Language leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |
| In Apache Ignite versions from 2.6.0 and before 2.17.0, configured Class Serialization Filters are ignored for some Ignite endpoints. The vulnerability could be exploited if an attacker manually crafts an Ignite message containing a vulnerable object whose class is present in the Ignite server classpath and sends it to Ignite server endpoints. Deserialization of such a message by the Ignite server may result in the execution of arbitrary code on the Apache Ignite server side. |
| @builder.io/qwik-city is the meta-framework for Qwik. When a Qwik Server Action QRL is executed it dynamically load the file containing the symbol. When an invalid qfunc is sent, the server does not handle the thrown error. The error then causes Node JS to exit. This vulnerability is fixed in 1.13.0. |
| Improper verification of the digital signature in ksojscore.dll in Kingsoft WPS Office in versions equal or less than 12.1.0.18276
on Windows allows an attacker to load an arbitrary Windows library. The patch released in version 12.2.0.16909 to mitigate CVE-2024-7262 was not restrictive enough. |
| Honeywell OneWireless
Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to
R322.3, R330.2 or the most recent version of this product2. |
| An escalation of privilege vulnerability in ASPECT could provide an attacker root access to a server when logged in as a "non" root ASPECT user. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| This vulnerability allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by uploading a specially crafted PAM upgrade file. |
| 2nd Order SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if administrator credentials become compromised.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group. |
| SQL Injection vulnerability in MegaBIP software allows attacker to disclose the contents of the database, obtain session cookies or modify the content of pages. This issue affects MegaBIP software versions through 5.12.1. |
| mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system. |
| The use of a weak cryptographic key pair in the signature verification process in WPS Office (Kingsoft) on Windows allows an attacker who successfully recovered the private key to sign components.
As older versions of WPS Office did not validate the update server's certificate, an Adversary-In-The-Middle attack was possible allowing updates to be hijacked. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM). |