| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SAP NetWeaver is vulnerable to an Information Disclosure vulnerability caused by the injection of malicious instructions into user configuration settings. An attacker with administrative privileges can craft these instructions so that when accessed by the victim, sensitive information such as user credentials is exposed. These credentials may then be used to gain unauthorized access to local or adjacent systems. This results in high impact to Confidentiality, with no significant effect on Integrity or Availability. |
| Under certain conditions Promotion Management Wizard (PMW) allows an attacker to access information which would otherwise be restricted.This has High impact on Confidentiality with Low impact on Integrity and Availability of the application. |
| Billing Software v1.0 is vulnerable to multiple Unauthenticated SQL Injection vulnerabilities. The 'username' parameter of the loginCheck.php resource does not validate the characters received and they are sent unfiltered to the database. |
| Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families:
* Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022
* Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020
* Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020
A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| The Relevanssi – A Better Search plugin for WordPress is vulnerable to time-based SQL Injection via the cats and tags query parameters in all versions up to, and including, 4.24.4 (Free) and <= 2.27.4 (Premium) due to insufficient escaping on the user supplied parameter and lack of sufficient preparation on the existing SQL query. This makes it possible for unauthenticated attackers to append additional SQL queries to already existing queries that can be used to extract sensitive information from the database. |
| Actualizer is a single shell script solution to allow developers and embedded engineers to create Debian operating systems (OS). Prior to version 1.2.0, Actualizer uses OpenSSL's "-passwd" function, which uses SHA512 instead of a more suitable password hasher like Yescript/Argon2i. All Actualizer users building a full Debian Operating System are affected. Users should upgrade to version 1.2.0 of Actualizer. Existing OS deployment requires manual password changes against the alpha and root accounts. The change will deploy's Debian's yescript overriding the older SHA512 hash created by OpenSSL. As a workaround, users need to reset both `root` and "Alpha" users' passwords. |
| The Frontend Dashboard plugin for WordPress is vulnerable to Privilege Escalation due to a missing capability check on the ajax_request() function in versions 1.0 to 2.2.7. This makes it possible for authenticated attackers, with Subscriber-level access and above, to control where the plugin sends outgoing emails. By pointing SMTP to their own server, attackers could capture password reset emails intended for administrators, and elevate their privileges for full site takeover. |
| Under certain conditions, SAP Landscape Transformation's PCL Basis module does not perform the necessary authorization checks, allowing authenticated users to access restricted functionalities or data. This can lead to a high impact on confidentiality with no impact on the integrity or availability of the application. |
| SAP S/4HANA Cloud Private Edition or on Premise (SCM Master Data Layer (MDL)) allows an authenticated attacker with SAP standard authorization to execute a certain function module remotely and replace arbitrary ABAP programs, including SAP standard programs. This is due to lack of input validation and no authorization checks. This has low Confidentiality impact but high impact on integrity and availability to the application. |
| SAP Service Parts Management (SPM) does not perform necessary authorization checks for an authenticated user, allowing an attacker to escalate privileges. This has low impact on Confidentiality, integrity and availability of the application. |
| Due to a security misconfiguration vulnerability, customers can develop Production Operator Dashboards (PODs) that enable outside users to access customer data when they access these dashboards. Since no mechanisms exist to enforce authentication, malicious unauthenticated users can view non-sensitive customer information. However, this does not affect data integrity or availability. |
| SAP S/4 HANA allows an authenticated attacker with user privileges to configure a field not intended for their access and create a custom UI layout displaying this field. On performing this step the attacker could gain access to highly sensitive information. This could cause a high impact on confidentiality and minimal impact on integrity and availability of the application. |
| SAP S4CORE OData meta-data property allows an authenticated attacker to access restricted information due to missing authorization check. This could cause a low impact on confidentiality but integrity and availability of the application are not impacted. |
| A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation. |
| The Newsletters plugin for WordPress is vulnerable to time-based SQL Injection via the ‘orderby' parameter in all versions up to, and including, 4.9.9.8 due to insufficient escaping on the user supplied parameter and lack of sufficient preparation on the existing SQL query. This makes it possible for authenticated attackers, with Contributor-level access and above, to append additional SQL queries into already existing queries that can be used to extract sensitive information from the database. |
| A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation. |
| A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords. |
| An improper isolation or compartmentalization vulnerability [CWE-653] in FortiClientMac version 7.4.2 and below, version 7.2.8 and below, 7.0 all versions and FortiVoiceUCDesktop 3.0 all versions desktop application may allow an authenticated attacker to inject code via Electron environment variables. |
| SQL injection vulnerability in DomainsPRO 1.2. This vulnerability could allow an attacker to retrieve, create, update and delete databases via the “d” parameter in the “/article.php” endpoint. |